Partitions Walls - Lindner Logic Hier sehen Sie eine Auswahl von Positionen aus diesem Gliederungspunkt, die Sie interessieren könnten.
Partition connection profile - setting profile shadow joint Floor, ceiling and wall connections must be made of 1mm galvanised steel sheet. Ground- and ceilling connection profiles should be designed so as to recede by the thickness of the wall panel. Tolerance compensation of +/- 15mm has to be possible in the floor and ceiling areas. Partition connection i
Construction physical requirements The following regarding building physics requirements must be complied with in accordance with the latest versions of regulations and standards and must be verified by the appropriate documents:   Sound insulation value as per ISO 140-03   Solid partition fire resistance rating F0/F30/F90 Normal sou
Supply of a demountable partition, double-shell modular type for a linear modular system   Structure, substructure, connections and panelling according to preliminary technical remarks   Surfaces: Profiles for floors /ceilings/connections: Coil COating RAL 9005 (according to Lindner) Joints, longitu
Fitting element for glazing element Requirements and structure as described above, but as a fitting element   Dimensions: Element width: 301-600 mm Element height: 2750 mm   Make: Lindner or comparable type Make offered: '....................'
Partition connection Partition connection to adjacent building component incl. tolerance compensation of approx. +/-10 mm.   Requirements regarding building physics: Fire resistance rating as per DIN 4102: F0   Dimensions: Partition connection joint: Approx. 20mm Element height: 2750mm   Make: Lindner or comparable type
90°-corner with metal panelling Structure, substructure, connections and panelling according to preliminary technical remarks   Surfaces: Floor/ceiling profiles: RAL 9005 (according to Lindner) Joints, longitudinal and transverse: Black 90°-outer corner in form of wall panel: RAL 9006 (according to Lindner) 90°-inside corner: RAL
Infill strip with chipboard Structure, substructure, connections and panelling according to preliminary technical remarks   For the integration of electrical installations in the partition.   Surfaces: Profiles for floors /ceilings/connections: Coil Coating RAL 9005 (according to Lindner) Joints, longitudinal and transverse: B
Infill strip with aluminium Structure, substructure, connections and panelling according to preliminary technical remarks   For the integration of electrical installations in the partition.   Surfaces: Profiles for floors /ceilings/connections: Coil Coating RAL 9005 (according to Lindner) Joints, longitudinal and transverse: B
Finishing element with aluminium panelling Structure, substructure, connections and panelling according to preliminary technical remarks. The finishing element, is carried out without a floor/ceiling joint.   Surfaces: Floor/ceiling profiles: Coil Coating RAL 9005 (according to Lindner) Joints, longitudinal and transverse: Black Finishing el
General technical remarks for glazed partition walls / partition walls The basic requirements for the system partitions are described in the following as well as in the architectural details. Bidders should cite any system-specific differences, which, however, will not be a criterion for exclusion. The design's equivalence should be demonstrated.   This invitation to t
Substructure for Glazed Partition Walls / Partition Walls The substructure of the partitions consists of galvanised, torsion-free steel profiles with a minimum thickness of 1.5mm. The stud profiles have to be suitable for accommodating seals and wall panels. In addition to this, they have to be designed in a way that horizontal electrification is possible
Void insulation for Glazed Partition Walls / Partition Walls The mineral fibre insulating materials must be installed such that they cannot slip off. They consist of inorganic materials in the form of panels.   Insulating materials to add weight to panels to improve soundproofing and fire resistance consist of plasterboard and/or plaster fibreboard materials.
Partition connection profile - setting profile shadow joint Floor, ceiling and wall connections must be made of 1mm galvanised steel sheet. Ground- and ceilling connection profiles should be designed so as to recede by the thickness of the wall panel. Tolerance compensation of +/- 15mm has to be possible in the floor and ceiling areas. Partition connection i
Construction physical requirements The following regarding building physics requirements must be complied with in accordance with the latest versions of regulations and standards and must be verified by the appropriate documents:   Sound insulation value as per ISO 140-03   Solid partition fire resistance rating F0/F30/F90 Normal sou
A2-panel, HPL-surface In the substructure described, wall panels are to be fastened using a hook-on system. The wall panels are made of A2 supporting panel (without coating).The partition void must be filled with mineral wool with a minimum thickness of 40mm and A2 building-material class.   The wall panels should be des
Supply of a demountable partition, double-shell modular type for a linear modular system   Structure, substructure, connections and panelling according to preliminary technical remarks   Surfaces: Profiles for floors /ceilings/connections: Coil Coating RAL 9005 (according to Lindner) Joints, longitu
Supply of a demountable partition, double-shell modular type for a linear modular system   Structure, substructure, connections and panelling according to preliminary technical remarks   Surfaces: Profiles for floors /ceilings/connections: Coil Coating RAL 9005 (according to Lindner) Joints, longitu
HPL-coated, horizontal joint Supply of a demountable partition, double-shell modular type for a linear modular system   Structure, substructure, connections and panelling according to preliminary technical remarks   Surfaces: Profiles for floors /ceilings/connections: Coil Coating RAL 9005 (according to Lindner) Joints, longitu
Fitting element for glazing element Requirements and structure as described above, but as a fitting element   Dimensions: Element width: 301-600 mm Element height: 2750 mm   Make: Lindner or comparable type Make offered: '....................'
Partition connection Partition connection to adjacent building component incl. tolerance compensation of approx. +/-10 mm.   Requirements regarding building physics: Fire resistance rating as per DIN 4102: F0   Dimensions: Partition connection joint: Approx. 20mm Element height: 2750mm   Make: Lindner or comparable type
90°-corner with chipboard panelling Structure, substructure, connections and panelling according to preliminary technical remarks   Surfaces: Floor/ceiling profiles: Coil Coating RAL 9005 (according to Lindner) Joints, longitudinal and transverse: Black 90°-Outer corner in form of wall panel Visible side/reverse side: melamine resin,
Infill strip with chipboard Structure, substructure, connections and panelling according to preliminary technical remarks   For the integration of electrical installations in the partition.   Surfaces: Profiles for floors /ceilings/connections: Coil Coating RAL 9005 (according to Lindner) Joints, longitudinal and transverse: B
Infill strip with aluminium Structure, substructure, connections and panelling according to preliminary technical remarks   For the integration of electrical installations in the partition.   Surfaces: Profiles for floors /ceilings/connections: Coil Coating RAL 9005 (according to Lindner) Joints, longitudinal and transverse: B
Remarks Lindner Logic 690 Remarks Lindner Logic 690   The basic requirements for the system partitions are described in the following as well as in the architectural details. Bidders should cite any system-specific differences, which, however, will not be a criterion for exclusion. The design's equivalence should be demonstr
Lindner Logic 690 - cross organization Optional integrated cross-organization.   Grooved aluminum profiles for the integration of different accessories.   Surface: anodised aluminium E6EV1   Dimensions: Organization rail height: mm above OKFFB   Make: Lindner Logic 690 or comparable type Make offered: '....................'

Herstellerinformation

Lindner Group KG
Bahnhofstraße 29 94424 Arnstorf

Tel +49 (0)8723 20-3700
Fax +49 (0)8723 20-13282
Bereich Trockenbau

Lindner – Bauen mit neuen Lösungen. Die Lindner Group ist Europas führender Spezialist in den Bereichen Innenausbau, Fassadenbau und Isoliertechnik. Mehr als 45 Jahre Erfahrung im „Bauen mit neuen Lösungen“, der Entwicklung und Ausführung von individuellen und fortschrittlichen Projektlösungen. Weltweit betreibt Lindner Produktionsstätten und Tochtergesellschaften in mehr als 20 Ländern.