Partition connection / partition connection profile Floor, ceiling and wall connections must be made of 1mm galvanised steel sheet. All connection profiles should be designed so as to recede by the thickness of the wall panel. Tolerance compensation of +/- 15mm has to be possible in the floor and ceiling areas.   Floor joint/base height for solid par
Construction physical requirements The following regarding building physics requirements must be complied with in accordance with the latest versions of regulations and standards and must be verified by the appropriate documents:   Sound insulation value as per ISO 140-03   Solid partition fire resistance rating F0/F30/F90 Normal sou
Hohlraumdämmung Glastrennwände / Trennwände Die Mineralfaserdämmstoffe, welche aus anorganischen Materialien in Plattenform bestehen, werden abrutschsicher eingebaut. Dämmstoffe zur Schalenbeschwerung für die Verbesserung der Schalldämmung und des Brandschutzes bestehen aus Gipskarton- bzw. Gipsfasermaterialien. Bei Verglasungen werden option
Wandanschluss - Wandanschlussprofil Boden-, Decken- und Wandanschlüsse sind aus verzinktem Stahlblech 1mm auszuführen. Alle Anschlussprofile sind um die Wandschalenstärke zurückspringend auszubilden. Ein Toleranzausgleich von +/- 15mm im Boden- und Deckenbereich muss möglich sein.   Bodenfuge/Sockelhöhe bei Vollwandelementen: 60mm De
Bauphysikalische Anforderungen Folgende bauphysikalische Anforderungen sind jeweils nach Vorschriften und Normen neuester Fassung zu beachten und durch Nachweise zu belegen:   Schalldämmmaß nach ISO 10140-2   Vollwände Feuerwiderstandklasse F0/F30/F90 normaler Schallschutz: Rw=42dB erhöhter Schallschutz: Rw=47dB hoher Schallschut
Versetzbare Verglasung in Modulbauweise im Achsrastersystem   Aufbau, Unterkonstruktion, Anschlüsse und Beplankung nach technischen Vorbemerkungen.   Die Verglasungselemente werden als Brüstungsverglasungen in die Vollwandkonstruktion eingebaut. Für die Beplankungsart der Brüstungs- bzw. Oberblende,
Anforderungen und Aufbau wie zuvor beschrieben. Die Ausführung erfolgt allerdings als Passelement.   Abmessungen: Elementbreite: 301-600mm Elementhöhe: 2750mm
Fitting element for glazing element Requirements and structure as described above, but as a fitting element   Dimensions: Element width: 301-600 mm Element height: 2750 mm   Make: Lindner or comparable type Make offered: '....................'
Partition connection Partition connection to adjacent building component incl. tolerance compensation of approx. +/-10 mm.   Requirements regarding building physics: Fire resistance rating as per DIN 4102: F0   Dimensions: Partition connection joint: Approx. 20mm Element height: 2750mm   Make: Lindner or comparable type
Infill strip with chipboard Structure, substructure, connections and panelling according to preliminary technical remarks   For the integration of electrical installations in the partition.   Surfaces: Profiles for floors /ceilings/connections: RAL 9005 Joints, longitudinal and transverse: Black Wall panel, visible side/rever
Monobloc Absorber - Corner Construction: The absorber shell is backwards displaced on one side in order to take the adjoining absorber element, which is also displaced backwards on one side and thrusted to the filling part. The attachment to the filling part is made by adhesive tape.
Fully glazed partition in double glazing studless Construction according to preliminary remarks Surface floor-/celing-/connecting profiles: RAL 9005 Surface glass holding profile: anodised aluminium E6/C-0 Glazing seals: Black   Glass pane side one 10mm ESG Glass pane side two 12mm VSG   Acoustic
Supply of a demountable partition, double-shell modular type for a linear modular system   Structure, substructure, connections and panelling according to preliminary technical remarks   Surfaces: Profiles for floors /ceilings/connections: RAL 9005 Joints, longitudinal and transverse: Black Wall pa
Aluminiumzarge S/NF room-high Supply of a demountablealuminium frame with modular design in a linear modular system. Installation flush with partition.   Structure, substructure, connections and paneling according to preliminary technical remarks.   The door frames are installed room-high.   Door leaf and hardware should be offe
Aluminium door frame DF (type 2) room-high Supply of a demountablealuminium frame with modular design in a linear modular system. Installation flush with partition.   Structure, substructure, connections and paneling according to preliminary technical remarks.   The door frames are installed room-high.   Door leaf and hardware should be offe
Cut-outs for switch panel NF-IS Cut-outs for switch panelfor electrical installation into partitions.   Diameter cut-out: 68 mm     Make: Lindner or comparable type Make offered: '..............................'
Sound insulation door HTB type E (49 mm, double leaf), HPL-laminated Object door with laminated intermediate layer in system door frame (see seperate position). Including installation of the hardware required. Double leaf.   Structure according to preliminary technical remarks.   Surface finish: HPL, 0,8 mm, dcor: 7035 Pearl (as producers standard-collection)   Edge
Smoke protection Bonus for Alu fire-resistant door T60-1 for   Requirement to smoke protection '..........'pieces
Electric strike Bonus for Alu fire-resistant door T60-1 for   Installed electric strike   Operation: Inward: door handle Schüco - Design Art.No.: 240181, stainless steel Outward: door pull Schüco Art.No.: 210714, stainless steel '..........'pieces
Door closer with free-swing function Door closer with free-swing function DORMA TS 99 FL EMR 1, EN 2-5   Slide-channel door closer according to EN 1154 in Contur Design with CE-label, for a door leaf width up to 1250 mm, with electrohydraulic hold-open adjustment, proven according to EN 1155 and free-swing function from a door opening
Smoke detector Smoke detector "DORMA"   Smoke detector for lintel- and ceiling installation. Smoke detector is necessary at a lintel height of 1m   Make: DORMA Type: RM colour: silver '..........'pieces
Hold-open magnets for a 2-leafed doors 2 pc. hold-open magnets, operation voltage 24 V DC, current consumption 60 mA, power consumption 1,5 watt, holding force 490 N. Metal-hold-open magnet with switch The galvanised magnet- and distance tube for floor and ceiling installation with swivelling magnet-head. Performance in standard length
Shelf system for combination with Lindner partition systems. The shelf system hooks into the vertical system joints. The system is available in two different variants: with or without lateral book supports. The shelf is either made of metal or wood. Optional, the shelf has got an upstand on the b
Wardrobe hook as additional equipment for Lindner partition systems. The suspension device hooks into the vertical system joints. The installation is tool-free. The wardrobe hook has got three round extracts for coat hangers. The ball made of stainless steel, which is superimposed in front, can be
Blinds - manual Manual blind for combination with Lindner glass partitions.   Application area: Blinds as light and privacy screen for the interior.   Variant: between the panes of the double glazing / bracket-mounted in front of centre glazing   Operation: The slats are adjusted on one side by means of a mechanica

Herstellerinformation

Lindner Group KG
Bahnhofstraße 29 94424 Arnstorf

Tel +49 (0)8723 20-3700
Fax +49 (0)8723 20-13282
Bereich Trockenbau - Allgemein

Lindner – Bauen mit neuen Lösungen. Die Lindner Group ist Europas führender Spezialist in den Bereichen Innenausbau, Fassadenbau und Isoliertechnik. Mehr als 45 Jahre Erfahrung im „Bauen mit neuen Lösungen“, der Entwicklung und Ausführung von individuellen und fortschrittlichen Projektlösungen. Weltweit betreibt Lindner Produktionsstätten und Tochtergesellschaften in mehr als 20 Ländern.