Products Hier sehen Sie eine Auswahl von Positionen aus diesem Gliederungspunkt, die Sie interessieren könnten.
Gable glazing as a hip roof Gable glazing as a hip roof   As addition to INDU LIGHT SKYLINE glass. The hip is made at the same inclination as the continuous rooflight itself.   In the hip area, the post profiles take the form of rafter and ridge bars.   All condensate is directed outwards in a controlled manner across several
Brackets for photovoltaic elements Brackets for photovoltaic elements   Bracket for a photovoltaic system to be mounted at a later date on the back of the shed. The brackets are mounted as the butt connection cover instead of spacer bars. With suitable mounting aids, the longitudinal sections of the photovoltaic panels can be mounted
Hard roofing Hard roofing   Addition to continuous rooflight defined in DIN 4102 Part 7, resistant to flying sparks and radiant heat.   Clear opening: Length: '..........' m * Width: '..........' m  
Ridge Ridge   of the continuous rooflight on the roof ridge at right angles to the ridge due to the position of the continous rooflight.   This ridge formation depends on the inclination of the roof surfaces with one-part or two-part load-bearing sections.
INDU LIGHT Wave Grid WG INDU LIGHT Wave Grid WG   For continuous hail and fall-through protection.   Ultra-stable corrosion-resistant fine steel mesh with latticing selected to achieve optimum light transmission, mounted at a distance of approx. 40 mm above the glazing.   Resistance to hail: Hail resistance classification
Addition to INDU LIGHT Wave Grid WG on Continuous Rooflight Flap / Rooflight Addition to INDU LIGHT Wave Grid WG on Continuous Rooflight Flap / Rooflight   For continuous hail and fall-through protection.   Ultra-stable corrosion-resistant fine steel mesh with latticing selected to achieve optimum light transmission, mounted at a distance of approx. 40 mm above the glazing.
INDU LIGHT upstand, not self-supporting INDU LIGHT upstand, not self-supporting   Steel plate thickness based on structural engineering requirements (Series of standards DIN EN 1990/EC 0, DIN EN 1991/EC 1, DIN EN 1993/EC3) 400 mm high, galvanised, lintel arranged perpendicular for maximum utilisation of aperture in building shell as a he
INDU LIGHT safety adapter INDU LIGHT safety adapter   Steel plate thickness based on structural engineering requirements, shaped section approx. 300 mm, galvanised, adapted to suit building substructure. To safeguard the 2nd draining level of the INDU LIGHT-continuous rooflight system, the adapter is inclined outwards
Top flashing Top flashing   as an addition to the INDU LIGHT steel upstand, comprising a 1.0 mm thickness of multi-canted rolled untreated aluminium plate on which the surface-mounted frame incl. proper edge finishers are mounted. The top flashing is prepared to receive the lower flashing on site.
Electrical pushbutton AP version Electrical pushbutton AP version for actuation of electr. ventilation system ('Open-Closed') Assembly, electrical connection and wiring on site!
INDU LIGHT alarm box ('On') CO2 PAK INDU LIGHT alarm box ('On') CO2 PAK   in AP version, for manual actuation of smoke and heat exhaust ventilator, painted red RAL 3000. Including one CO2 cartridge, glass cover and an impact valve in the AP version.
Addition 24V DC 'IO' Addition 24V DC 'IO'   Electromagnet installed as addition to alarm box near manual activation switch in alarm box. The electrical wiring and connection are performed on site.
SHEV emergency activation station 24V SHEV emergency activation station 24V   For activation of the electromagnet in the C02 alarm box (delivery only!). Activation options, e.g. via external potential-free contact (e.g. central fire alarm system) or directly via the SHEV emergency activation station 24 V connected smoke detectors and/or
Compressed air single pipeline Compressed air single pipeline   6 mm x 1 mm copper, including all screw connections and mountings. Visible, routed on plaster. The length is dependent on the position of the control box. Billed according to dimensions.
Pneumatic double pipeline Pneumatic double pipeline   6 mm x 1 mm copper, including all screw connections and mountings. Visible, routed across plaster. The length is dependent on´the position of the control box. Billed by additional dimension.
INDU LIGHT maintenance unit INDU LIGHT maintenance unit   comprising a water separator with pressure gauge and pressure reducer (compressed air supply on site).
Pressure switch PED 250 V Pmax Pressure switch PED 250 V Pmax   ≥ 3 bar to 12 bar Pmax 60 bar for conversion of pneumatic pressure into an electrical impulse, for voltages between 12 V and 230 V. Assembly takes place in the pipeline on the alarm box or at the SHEV flap.   For activation of BMA, door controls, GLT et al. Electrica
Specialist commissioning of SHEV Specialist commissioning of SHEV   In acc. with state building code (LBO) incl. specialist fees. Including the costs for the service engineer, for new CO2 cartridges, closing of the opened SHEV flaps and recommissioning of the system.
VdS acceptance VdS acceptance   Costs for single acceptance of the SHEV system acc. to DIN 18232 or VdS 2159 by the Verband der Schadensversicherer e.V. in Cologne (trade association of insurers of physical damage).
Construction site flat fee Construction site flat fee   for freight, travel to site, construction site equipment, unloading and transportation on the roof.
Freight flat fee Freight flat fee   for deliver duty paid, without unloading and without assembly
Planning documents and structural engineering calculations Planning documents and structural engineering calculations   Drafting of planning documents for continuous rooflight (incl. connection to adjacent roof component) and structural engineering calculations for the continuous rooflight.
Documentation flat fee Documentation flat fee   Drafting of revision documents for all safety-related components supplied.
Handover of the SHEV installation Handover of the SHEV installation   with function test and instruction of a representative of the site general manager, acceptance and handover of the functional verification document. None of the costs for auditors or specialists are covered. Any further presentation is a billable item.
Lifting platform/equipment provision for pipework assembly Lifting platform/equipment provision for pipework assembly

Herstellerinformation

INDU LIGHT Produktion & Vertrieb GmbH
Willi-Brundert-Straße 3 06132 Halle/Saale

E-Mail halle@indu-light.de
Internet  www.indu-light.de
Bereich Dach

INDU LIGHT entwickelt, produziert und vertreibt seit über 25 Jahren innovative Dachverglasungen aus Glas und Kunststoff mit Rauchabzug für den vorbeugenden Brandschutz.

Stand 21.08.2019   Texte 362   Bilder 8