Turn/tilt [Basis] 11.x Turn/tilt fitting for overlap sash   Opening type specification: Basic turn/tilt fitting with top mounted hinge side for overlap sash   - admissible sash weight up to 160 kg - size of retainer arm to suit minimum sash width - gear with safeguard against incorrect operation - corrosion resistanc
Turn/tilt [Burglar resistance RC 1 N, RC 2 N, RC 2] 11.x Turn/tilt fitting for overlap sash, burglar resistant RC 1/RC 2   Opening type specification: Turn/tilt fitting with top-mounted hinge side for overlap sash, burglar resistant, resistance classes RC 1 N/ RC 2 N/ RC 2 in compliance with DIN EN 1627:2011   - admissible sash weight up to 160 kg -
Turn/tilt [Burglar resistance RC 3] 11.x Turn/tilt fitting for overlap sash, burglar resistant RC 3   Opening type specification: Turn/tilt fitting with top-mounted hinge side for overlap sash, burglar resistant, resistance class RC 3 in compliance with DIN EN 1627:2011   - admissible sash weight up to 160 kg - size of retainer arm to
Turn/tilt concealed [Basis] 11.x Concealed turn/tilt fitting for overlap sash   Opening type specification: Basic turn/tilt fitting with concealed hinge side for overlap sash   With this type of fitting, no part of the fitting is visible when the window is closed except for the window handle. All functional parts are within th
Turn/tilt concealed [Burglar resistance RC 1 N, RC 2 N, RC 2] 11.x Concealed turn/tilt fitting for overlap sash, burglar resistant RC 1/RC 2   Opening type specification: Turn/tilt fitting with concealed hinge side for overlap sash, burglar resistant, resistance classes RC 1 N/ RC 2 N/ RC 2 in compliance with DIN EN 1627:2011   With this type of fitting, no pa
Turn/tilt concealed [Burglar resistance RC 3] 11.x Concealed turn/tilt fitting for overlap sash, burglar resistant RC 3   Opening type specification: Turn/tilt fitting with concealed hinge side for overlap sash, burglar resistant, resistance class RC 3 in compliance with DIN EN 1627:2011   With this type of fitting, no part of the fitting is vi
Modular system 11.x Opening limiter, modular system   The installation of opening limiters is necessary when the sash movement of window units is restricted, e.g. by walls, reveals or by façade elements.   Opening limiters also prevent damage to windows and adjacent building elements, and protect window hardware f
Force-absorbing 11.x Opening limiter, force-absorbing   The installation of opening limiters is necessary when the sash movement of window units is restricted, e.g. by walls, reveals or by façade elements.   Opening limiters also prevent damage to windows and adjacent building elements, and protect window hardware
Turn [Basis] 11.x Turn fitting for ventilation flap   Opening type specification: Basic turn fitting with top mounted hinge side for ventilation flap   - admissible sash weight up to 80 kg - gear with safeguard against incorrect operation - corrosion resistance compliant with DIN EN 1670, Class 5     Parts list:
Turn Concealed [Basis] 11.x Concealed turn fitting for ventilation flap   Opening type specification: Basic turn fitting with concealed hinge side for ventilation flap   With this type of fitting, no part of the fitting is visible when the window is closed except for the window handle. All functional parts are within the
Magnetic contacts 11.x Locked state monitoring   The components feature magnetic contacts as: a) Changeover contacts for control systems b) Alarm contacts certified to VdS Class B c) Alarm contacts certified to VdS Class C (Delete item not applicable).   The contacts have a cable length of: a) 6 m b) 10 m (Delete ite
Basic protection - burglar resistance 11.x Hardware basic protection for burglar resistance   Specifications: Each component features two additional locking points for increased basic protection for burglar resistance. The additional locking points must have mushroom head bolts and the strikers must be fitted with a T-groove positively
Hold-open limiter 11.x Hold-open limiter   Specifications: Components with turn-only hardware feature opening restrictors.   Installation location: a) at bottom b) at top (Delete item not applicable).   The opening restrictor must limit the opening angle of the sash to 90°. From an approximate 15° angle until the ful
Concealed side hinge, 200 kg 11.x Concealed side hinge, 200 kg   Specifikations: The components feature concealed hinges. The hinges must be approved for sash weights of up to 200 kg.
Vent sash [Standard] 11.x Roof light vent sash fitting standard for vent sash in façades   Performance requirements: All fitting components are system-related brand fittings.   - permitted sash weight 100 kg / 130 kg - max. opening angle 90° - installation positions 10° - 70° to the horizontal   Parts list:   a) 3 part
Top-hung window [Standard] 11.x Top hung fitting standard for all-glass sash in façades   Performance requirements: All fitting components are system-related brand fittings.   - max. permissible sash width 1500 mm - max. permissible sash height 1500 mm - centrally located surface mounted gear - adjustable locking parts - max.
Parallel-opening ventilation [manually] (new) 11.x Parallel-opening ventilation leaf for all-glass leaves in façades operated manually   Performance requirements: All fitting parts are system-specific brand hardware.   - Max. permissible leaf width: 1200 mm - Max. permissible leaf height: 2500 mm - Counter-rotating drives vertically located to
Parallel-opening ventilation [motor-driven] (new) 11.x Parallel-opening ventilation leaf for all-glass leaves in façades driven by motor   Performance requirements: All fitting parts are system-specific brand hardware.   - Max. permissible leaf width: 1500 mm (landscape format up to 2000 mm) - Max. permissible leaf height: 3000 mm (landscape format
Single-leaf hinged door [Standard] 11.x Standard fittings for single-leaf inward and outward opening hinged door   Performance requirements: All fitting components are system-related branded fittings.   - permitted sash weight depending on hinge up to 200 kg - lock forends and locking plates in Niro - visible fittings in AL-EV1/RAL 9
Single-leaf hinged door [DIN EN 179] 11.x Fittings for single-leaf outward opening emergency exit door in accordance with DIN EN 179   Preliminary remark Emergency exits in accordance with DIN EN 179 are designed for buildings which are not subjected to public traffic and whose visitors know how to operate the escape doors. These can a
Single-leaf hinged door [DIN EN 1125] 11.x Fittings for single-leaf outward opening panic door in accordance with DIN EN 1125   Preliminary remark: Panic doors in accordance with DIN EN 1125 are used in public buildings where visitors do not know how to operate the escape doors and it must also be possible to operate them in the event o
Double-leaf hinged door [Standard] 11.x Fittings for standard double-leaf inward and outward opening hinged door   Performance requirements: All fitting components are system-related branded fittings.   - permitted sash weight depending on hinge up to 200 kg - lock forends and locking plates in Niro - visible fittings in AL-EV1/RAL 9
Double-leaf hinged door [DIN EN 179] 11.x Fittings for double-leaf outward opening emergency exit door in accordance with DIN EN 179   Preliminary remark: Emergency exits in accordance with DIN EN 179 are designed for buildings which are not subjected to public traffic and whose visitors know how to operate the escape doors. These can
Double-leaf hinged door [DIN EN 1125] 11.x Fittings for double-leaf outward opening panic door in accordance with DIN EN 1125   Preliminary remark: Panic doors in accordance with DIN EN 1125 are used in public buildings where visitors do not know how to operate the escape doors and it must also be possible to operate them in the event o

Manufacturer's information

Hydro Building Systems UK Ltd.
Silkwood Park Wakefield WF5 9TG - United Kingdom

Tel. +44 (0)845 6028799
Fax +44 (0)1924 232300
E-Mail info@wicona.co.uk
Internet  www.wicona.co.uk
Internet  www.wictip.com
Category Profile systems

Modular aluminium profile systems for façades, windows, doors and glazed annexes, highly insulated / uninsulated series, stick constructions, unitized façades, energy efficient façades, structural glazings, lifting sliding doors, folding sliding doors, safety technique, fire protection façades / windows, fire protection / smoke control doors, burglar resistance, bullet resistance, system fittings

Last modified 07.05.2019   Texts 167   Pictures 45